Articles:2014,Vol:19,Issue(3):150-172
Citation:
HUANG Hui, WANG Qiusheng, GAO Jie, YANG Jiaqi, XU Xiaodong. Establishment and Analysis of the Fault Tree for the Oil Transfer Pump System in CNPC Work Zone[J]. International Journal of Plant Engineering and Management, 2014, 19(3): 150-172

Establishment and Analysis of the Fault Tree for the Oil Transfer Pump System in CNPC Work Zone
HUANG Hui1
1. School of Management,Northwestern Polytechnical University,Xi'an 710072,P.R. China;
2. Huaxin Consulting Co.,Ltd,Hangzhou 310014,P.R. China
Abstract:
The reliability of the equipment is very important for the large petrochemical industry,especially for oil pump as the core component of driving equipment. In order to reduce the loss of the enterprise brought by equipment failure,it is need to find those reasons which may lead to equipment failure and take some preventive measures as early as possible. This article analyzes the failure of the oil transfer pump system in CNPC work zone systematically,qualitatively and quantitatively,using the fault tree analysis method. Then 105 groups of minimal cut sets are found,and the probability of system failure after a certain time operation is calculated by using Weibull distribution. Combined with specific requirements of reliability,the work zone may make a scientific decision of plant maintenance cycle according to the conclusion.
Key words:    fault tree    reliability    Weibull distribution    plant maintain and management   
Received: 2014-07-25     Revised:
DOI: 10.13434/j.cnki.1007-4546.2014.0303
Funds: This paper was supported by The Ministry of Education of Humanities,and Social Science Project (NO.11YJC630071),The National Social Science Fund Project (NO.13BGL064).
Corresponding author:     Email:
Author description:
Service
PDF(804KB) Free
Print
Authors

References:
[1] Zeng S K,Zhao T D,Zhang J G,et al. The course of design and analysis of system reliability[M]. Beijing: Beihang University Press, 2004 (in Chinese)
[2] He Z W,Xu Y. Application of FTA method to reliability analysis of vacuum resin shot dosing equipment [J]. International Journal of Engineering and Management, 2002, 7(1):1-7
[3] Chen L,Wang G L,Meng H R,et al. An analysis of fault tree of an oil-well pump[J].ACTA Petrolei Sinica, 1995, 16(3):145-151
[4] Zheng L,Yang T,Zheng D. Application of fault tree analysis method in fault forecast[J].Electric Age, 2005, 8:84-85 (in Chinese)
[5] Yan F X,Dong Y H,Gao H L. Application of fault tree analysis to the failure analysis of oil and gas pipelines [J]. Journal of Xi' an Petroleum Institute (Natural Science Edition),2003, 18(1):47-50 (in Chinese)
[6] Chen C,Wang M M,Zhou X H. Fault tree analysis method of gas turbine-driven compressor [J]. Petroleum Planning & Engineering, 2009,20 (3): 8-10,41 (in Chinese)
[7] Yu X H,Zhang L B,Wang Z H,et al.Reliability life analysis of the equipment based on new weibull distribution parameter estimation method[J]. Journal of Mechanical Strength, 2007, 29(6):932-936 (in Chinese)
[8] Ling D. Research on weibull distribution and its applications in mechanical reliability engineering [D]. Chengdu: University of Electronic Science and Technology of China,2010 (in Chinese)
[9] Cao Z. J. Two parameters weibull distribution in automotive field failure forecast[J]. Journal of Liaoning Institute of Science and Technology, 2011, 13(4):23-24 (in Chinese)