Abstract:
Based on the inspection and diagnosis of the vibration and noise in the process of using the two bridge crane in the hydropower station, the measurements to eliminate the hidden trouble of equipment was put forward and the good results were gotten.
Key words:    reducer    abrasion    vibration    improvement   
Received: 2017-02-25     Revised:
DOI: 10.13434/j.cnki.1007-4546.2017.0208
Corresponding author:     Email:
Author description: LIN Jia-yang is a senior engineer, Fujian Shuikou Power Generation Group Co., Ltd. His research interests include hydraulic machinery operation of hydropower station, and equipment maintenance technology. ljyfff@sina.com
Service
PDF(93KB) Free
Print
Authors
LIN Jia-yang

References:
[1] GB/T 3811-2008 Design rules for cranes[S]
[2] GB/T 14405-2011 Bridge crane for general purpose[S]
[3] Liu D Q. The basic requirements of crane safe operation[J]. Science and Technology Communication, 2014,(11):49-50
[4] Kang F M. Causes and control of leakage oil of crane reducer[J]. Engineering Machinery and Maintenance, 1998, (5):24-25
[5] Yang Q P, Li Y L. Statistical analysis and prevention of crane accidents in China[J]. Mechanical Management Development, 2011, (2):140-141